BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//linuxsoftware.nz//NONSGML Joyous v1.4//EN
BEGIN:VEVENT
SUMMARY:A novel treatment planning method for proton FLASH  radiotherapy: 
 Combining FLASH with VMAT
DTSTART:20230919T140000Z
DTEND:20230919T160000Z
DTSTAMP:20260813T105707Z
UID:10061ea1-f787-4eb1-a28a-34b6f1a80ef8
SEQUENCE:1
CREATED:20230911T210338Z
DESCRIPTION: In this work\, we propose a new treatment planning method for
  multi-beam FLASH  radiotherapy (Stitching FLASH) that combines FLASH deli
 vered by proton beams\, with volumetric modulated arc therapy (VMAT). The 
 Stitching FLASH method requires the target to be divided into different se
 ctions.  For sections close to an Organ-at-risk (OAR)\, proton FLASH beams
  were used to deliver  radiation dose. For the remaining target volume\, V
 MAT was used to achieve optimal  target coverage. To validate the Stitchin
 g FLASH method\, we used matRad\, a treatment planning toolkit  developed 
 by DKFZ. We applied it first\, as proof of concept\, to irradiate three sp
 herical  phantoms surrounded by several OARs and second\, to irradiate a c
 ervical spinal cord  tumor\, which we then compared to the clinical VMAT p
 lan. In our phantoms study\, we managed to fulfil the minimum dose and dos
 e-rate  conditions for protecting the OARs with FLASH\, while obtaining ex
 cellent target  coverage and superb dose conformity and homogeneity. For t
 he spinal cord tumor  irradiation\, we were able to significantly increase
  the Clinical Target Volume (CTV) coverage and minimum dose\, while keepin
 g the doses in the OARs below the clinical  thresholds using the FLASH pro
 tecting effect. With the novel FLASH treatment planning method proposed in
  this work\, we have  demonstrated that it is possible to protect critical
  OARs\, while maintaining excellent target coverage and dose homogeneity\,
  as well as conformity. This shows that  the Stitching FLASH method is pro
 mising for proton FLASH radiotherapy 
LAST-MODIFIED:20230911T210338Z
LOCATION:Online
URL:http://df.vps.tecnico.ulisboa.pt/pt/eventos/a-novel-treatment-planning
 -method-for-proton-flash-radiotherapy-combining-flash-with-vmat/
X-ALT-DESC;FMTTYPE=text/html:<p data-block-key="2wknr"> In this work\, we 
 propose a new treatment planning method for multi-beam FLASH  radiotherapy
  (Stitching FLASH) that combines FLASH delivered by proton beams\, with vo
 lumetric modulated arc therapy (VMAT). The Stitching FLASH method requires
  the target to be divided into different sections.  For sections close to 
 an Organ-at-risk (OAR)\, proton FLASH beams were used to deliver  radiatio
 n dose. For the remaining target volume\, VMAT was used to achieve optimal
   target coverage. To validate the Stitching FLASH method\, we used matRad
 \, a treatment planning toolkit  developed by DKFZ. <br/><br/>We applied i
 t first\, as proof of concept\, to irradiate three spherical  phantoms sur
 rounded by several OARs and second\, to irradiate a cervical spinal cord  
 tumor\, which we then compared to the clinical VMAT plan. In our phantoms 
 study\, we managed to fulfil the minimum dose and dose-rate  conditions fo
 r protecting the OARs with FLASH\, while obtaining excellent target  cover
 age and superb dose conformity and homogeneity. <br/><br/>For the spinal c
 ord tumor  irradiation\, we were able to significantly increase the Clinic
 al Target Volume (CTV) coverage and minimum dose\, while keeping the doses
  in the OARs below the clinical  thresholds using the FLASH protecting eff
 ect. With the novel FLASH treatment planning method proposed in this work\
 , we have  demonstrated that it is possible to protect critical OARs\, whi
 le maintaining excellent target coverage and dose homogeneity\, as well as
  conformity. This shows that  the Stitching FLASH method is promising for 
 proton FLASH radiotherapy </p>